ABSTRACT

OBJECTIVE: The COVID-19 pandemic has precipitated widespread shortages of filtering facepiece respirators (FFRs) and the creation and sharing of proposed substitutes (novel designs, repurposed materials) with limited testing against regulatory standards. We aimed to categorically test the efficacy and fit of potential N95 respirator substitutes using protocols that can be replicated in university laboratories. SETTING: Academic medical centre with occupational health-supervised fit testing along with laboratory studies. PARTICIPANTS: Seven adult volunteers who passed quantitative fit testing for small-sized (n=2) and regular-sized (n=5) commercial N95 respirators. METHODS: Five open-source potential N95 respirator substitutes were evaluated and compared with commercial National Institute for Occupational Safety and Health (NIOSH)-approved N95 respirators as controls. Fit testing using the 7-minute standardised Occupational Safety and Health Administration fit test was performed. In addition, protocols that can be performed in university laboratories for materials testing (filtration efficiency, air resistance and fluid resistance) were developed to evaluate alternate filtration materials. RESULTS: Among five open-source, improvised substitutes evaluated in this study, only one (which included a commercial elastomeric mask and commercial HEPA filter) passed a standard quantitative fit test. The four alternative materials evaluated for filtration efficiency (67%-89%) failed to meet the 95% threshold at a face velocity (7.6 cm/s) equivalent to that of a NIOSH particle filtration test for the control N95 FFR. In addition, for all but one material, the small surface area of two 3D-printed substitutes resulted in air resistance that was above the maximum in the NIOSH standard. CONCLUSIONS: Testing protocols such as those described here are essential to evaluate proposed improvised respiratory protection substitutes, and our testing platform could be replicated by teams with similar cross-disciplinary research capacity. Healthcare professionals should be cautious of claims associated with improvised respirators when suggested as FFR substitutes.


Subject(s)
COVID-19 , Occupational Exposure , Respiratory Protective Devices , Adult , Equipment Design , Humans , N95 Respirators , Pandemics/prevention & control , SARS-CoV-2 , United States , Ventilators, Mechanical
2.
Acad Radiol ; 28(2): 158-165, 2021 02.
Article in English | MEDLINE | ID: covidwho-1064684

ABSTRACT

RATIONALE AND OBJECTIVE: Three-dimensional (3D) printing allows innovative solutions for personal protective equipment, particularly in times of crisis. Our goal was to generate an N95-alternative 3D-printed respirator that passed Occupational Safety and Health Administration (OSHA)-certified quantitative fit testing during the COVID-19 pandemic. MATERIALS AND METHODS: 3D printed prototypes for N95 solutions were created based on the design of commercial N95 respirators. Computed tomography imaging was performed on an anthropomorphic head phantom wearing a commercially available N95 respirator and these facial contour data was used in mask prototyping. Prototypes were generated using rigid and flexible polymers. According to OSHA standards, prototypes underwent subsequent quantitative respirator fit testing on volunteers who passed fit tests on commercial N95 respirators. RESULTS: A total of 10 prototypes were 3D printed using both rigid (n = 5 designs) and flexible materials (n = 5 designs), Prototypes generated with rigid printing materials (n = 5 designs) did not pass quantitative respirator fit testing. Three of the five prototypes with flexible materials failed quantitative fit testing. The final two prototypes designs passed OSHA-certified quantitative fit tests with an overall mean fit factor of 138 (passing is over 100). CONCLUSION: Through rapid prototyping, 3D printed N95 alternative masks were designed with topographical facial computed tomography data to create mask facial contour and passed OSHA-certified quantitative respiratory testing when flexible polymer was used. This mask design may provide an alternative to disposable N95 respirators in case of pandemic-related shortages. Furthermore, this approach may allow customization for those that would otherwise fail fit testing on standard commercial respirators.


Subject(s)
COVID-19 , Pandemics , Equipment Design , Humans , Masks , Materials Testing , N95 Respirators , Printing, Three-Dimensional , SARS-CoV-2 , Tomography, X-Ray Computed